Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ocul Immunol Inflamm ; 29(6): 1090-1101, 2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-32130054

RESUMO

Purpose: To find immunomediator combinations which could sensitively indicate keratoconus progression.Methods: Tear samples of 42 patients with keratoconus were collected at baseline and at the end of a one-year follow-up. The concentrations of 13 mediators were measured by CBA. Based on Pentacam HR examination, eyes were divided into a non-progressive and a progressive group.Results: At the end of the follow-up, significant differences were observed in the release of IFNγ, IL-13, IL-17A, CCL5, MMP-13 and PAI-1 between the two groups. Changes in five Pentacam parameters correlated positively with changes in IFNγ, IL-13, IL-17A, CXCL8, CCL5, TIMP-1 and t-PA. We found that tear level of IL-13 in combination with NGF can predict the progression of keratoconus with 100% specificity and 80% sensitivity.Conclusion: The findings of our longitudinal study may underscore the importance of NGF and IL-13 tear levels in the prediction of keratoconus progression.


Assuntos
Proteínas do Olho/metabolismo , Interleucina-13/metabolismo , Ceratocone/diagnóstico , Fator de Crescimento Neural/metabolismo , Lágrimas/metabolismo , Adolescente , Adulto , Idoso , Progressão da Doença , Feminino , Humanos , Ceratocone/metabolismo , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Microscopia com Lâmpada de Fenda , Acuidade Visual/fisiologia , Adulto Jovem
2.
Sci Rep ; 9(1): 3419, 2019 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-30833606

RESUMO

Our purpose was to prospectively analyze the age-related changes of corneal Scheimpflug parameters in healthy subjects. Thirty-five eyes of 35 volunteers (age 14-67 years) were investigated with an average interval of 3.6 years. Changes of corneal parameters (flattest keratometric reading at anterior (K1F) and posterior surface (K1B), steepest keratometric reading at anterior (K2F) and posterior surface, anterior astigmatism, posterior astigmatism (AstigB), flat axis of anterior and posterior astigmatism (AxisB), thinnest pachymetric value (PachyMin), corneal volume (CV10-mm)) were analyzed. K1F and K2F decreased significantly during observation and showed stronger decrease in younger than in older individuals. Higher values proved to be more stable. K1B decreased significantly and the degree of decrease was dependent on its baseline value and age: in young subjects low values increased, high values decreased. AstigB decreased significantly and showed a baseline-dependent significant increase from lower and a significant decrease from higher initial values. Over time, the mean AxisB shifted significantly. PachyMin and CV decreased significantly with age, especially from higher baseline values in younger subjects. The results of this longitudinal study suggest that both corneal surfaces change significantly with age. We demonstrate for the first time that age and baseline values influence age-related changes of corneal parameters.


Assuntos
Envelhecimento/fisiologia , Córnea/fisiologia , Adolescente , Adulto , Idoso , Astigmatismo/diagnóstico por imagem , Astigmatismo/fisiopatologia , Córnea/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Orv Hetil ; 159(17): 671-676, 2018 Apr.
Artigo em Húngaro | MEDLINE | ID: mdl-29681179

RESUMO

INTRODUCTION AND AIM: To present our results on femtosecond laser-assisted penetrating keratoplasty. PATIENTS AND METHOD: Twenty-five eyes of 25 patients underwent surgery with the following indications: pseudophakic bullous keratopathy (n = 10), keratoconus (n = 4), corneal dystrophy (n = 5), corneal scar (n = 4), band keratopathy (n = 2). Trephination of both the donor and recipient corneas were performed with VisuMax femtosecond laser device (Carl Zeiss Meditec AG, Jena, Germany). In each case, trephinaton of the donor tissue was performed first with an artificial anterior chamber (Moria, Antony, France). For the surgical plan and in the postoperative period we obtained different corneal imaging modalities. The corneal power was measured with corneal topography (TMS-4, Tomey, Nürnberg, Germany) and Scheimpflug tomography (Pentacam HR, Oculus, Wetzlar, Germany). The central corneal thickness was evaluated with Pentacam and corneal endothelial cell density was measured with specular microscopy (SP3000P, Topcon, Tokyo, Japan). The corneal structure was imaged with anterior segment optical coherence tomography (Visante, Carl Zeiss Meditec AG). All measurements were performed every 3 months in the first year and yearly thereafter. The follow-up period was 3 years in every case. RESULTS: The corrected decimal visual acuity showed an improvement from a preoperative 0.1 ± 0.1 to a postoperative 0.71 ± 0.18 value at the end of the follow-up period (p = 0.03). All corneal grafts maintained their transparency, there were no immunological rejection during the follow-up. Topographical astigmatism was 4.5 ± 3.1 D in the first month; it showed a decreasing tendency, but there was no significant change in the 3-year period. The mean central corneal thickness changed with 60 µm during the follow-up; there was no significant difference between the first month (564 ± 52 µm) and the third year (596 ± 64 µm) mean pachymetry values (p = 0.1). The mean endothelial cell density decreased first, then remained stable, but did not change significantly from the first (1641 ± 433 cells/mm2) to the last postoperative visit (1220 ± 391 cells/mm2, p = 0.1). CONCLUSIONS: In the case of femtosecond laser-assisted penetrating keratoplasty, trephination of the donor and recipient cornea is performed automatically in a highly precise fashion. The accurate cutting surface provides excellent wound apposition and healing. Both anatomical and functional rehabilitation of patients undergoing surgery are favourable and fast. Orv Hetil. 2018; 159(17): 671-676.


Assuntos
Doenças da Córnea/cirurgia , Ceratoplastia Penetrante/métodos , Terapia a Laser/métodos , Acuidade Visual , Distrofias Hereditárias da Córnea/cirurgia , Feminino , Seguimentos , Humanos , Ceratocone/cirurgia , Masculino , Doadores de Tecidos , Resultado do Tratamento
4.
Invest Ophthalmol Vis Sci ; 58(3): 1834-1842, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28358949

RESUMO

Purpose: Rare interchange haplotypes in exon 3 of the OPN1LW and OPN1MW opsin genes cause X-linked myopia, color vision defect, and cone dysfunction. The severity of the disease varies on a broad scale from nonsyndromic high myopia to blue cone monochromatism. Here, we describe a new genotype-phenotype correlation attributed to rare exon 3 interchange haplotypes simultaneously present in the long- and middle-wavelength sensitive opsin genes (L- and M-opsin genes). Methods: A multigenerational family with X-linked high myopia and cone dystrophy was investigated. Results: Affected male patients had infantile onset myopia with normal visual acuity and color vision until their forties. Visual acuity decreased thereafter, along with the development of severe protan and deutan color vision defects. A mild decrease in electroretinography response of cone photoreceptors was detected in childhood, which further deteriorated in middle-aged patients. Rods were also affected, however, to a lesser extent than cones. Clinical exome sequencing identified the LVAVA and MVAVA toxic haplotypes in the OPN1LW and OPN1MW opsin genes, respectively. Conclusion: Here, we show that LVAVA haplotype of the OPN1LW gene and MVAVA haplotype of the OPN1MW gene cause apparently nonsyndromic high myopia in young patients but lead to progressive cone-rod dystrophy with deuteranopia and protanopia in middle-aged patients corresponding to a previously unknown disease course. To the best of our knowledge, this is the first report on the joint effect of these toxic haplotypes in the two opsin genes on chromosome X.


Assuntos
Cromossomos Humanos X/genética , Defeitos da Visão Cromática/genética , DNA/genética , Doenças Genéticas Ligadas ao Cromossomo X/genética , Miopia/genética , Células Fotorreceptoras Retinianas Bastonetes/patologia , Opsinas de Bastonetes/genética , Adolescente , Adulto , Criança , Defeitos da Visão Cromática/diagnóstico , Defeitos da Visão Cromática/metabolismo , Progressão da Doença , Eletrorretinografia , Feminino , Estudos de Associação Genética , Doenças Genéticas Ligadas ao Cromossomo X/diagnóstico , Doenças Genéticas Ligadas ao Cromossomo X/metabolismo , Genótipo , Haplótipos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico , Miopia/metabolismo , Linhagem , Fenótipo , Reação em Cadeia da Polimerase , Células Fotorreceptoras Retinianas Bastonetes/metabolismo , Opsinas de Bastonetes/metabolismo , Adulto Jovem
5.
BMC Ophthalmol ; 17(1): 3, 2017 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-28086913

RESUMO

BACKGROUND: Toric intraocular lens (IOL) implantation can be an effective method for correcting corneal astigmatism in patients with vitreoretinal diseases and cataract. Our purpose is to report the outcome of toric IOL implantation in two cases - a patient with scleral-buckle-induced regular corneal astigmatism and a patient with keratoconus following pars plana vitrectomy. As far as we are aware, there are no reported cases of toric IOL implantation in a vitrectomized eye with keratoconus nor of toric IOL implantation in patients with scleral-buckle-induced regular corneal astigmatism. CASE PRESENTATION: Two patients with myopia and high corneal astigmatism underwent cataract operation with toric IOL implantation after posterior segment surgery. Myopia and high astigmatism (>2.5 diopter) were caused by previous scleral buckling in one case and by keratoconus in the other case. Pre- and postoperative examinations during the follow-up of included uncorrected and spectacle corrected distance visual acuity (UCDVA/CDVA), automated kerato-refractometry (Topcon), Pentacam HR, IOL Master (Zeiss) axial length measurements and fundus optical coherence tomography (Zeiss). One year postoperatively, the UCDVA and CDVA were 20/25 and 20/20 in both cases, respectively. The absolute residual refractive astigmatism was 1.0 and 0.75 Diopters, respectively. The IOL rotation was within 3° in both eyes, therefore IOL repositioning was not necessary. Complications were not observed in our cases. CONCLUSION: These cases demonstrate that toric IOL implantation is a predictable and safe method for the correction of high corneal astigmatism in complicated cases with different origins. Irregular corneal astigmatism in keratoconus or scleral-buckle-induced regular astigmatisms can be equally well corrected with the use of toric IOL during cataract surgery. Previous scleral buckling or pars plana vitrectomy seem to have no impact on the success of the toric IOL implantation, even in keratoconus. IOL rotational stability and refractive predictability in patients with a previous vitreoretinal surgery can be as good as in uncomplicated cases.


Assuntos
Astigmatismo/cirurgia , Doenças da Córnea/cirurgia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Facoemulsificação/métodos , Segmento Posterior do Olho/cirurgia , Idoso , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
6.
Indian J Ophthalmol ; 64(3): 246-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27146942

RESUMO

In this study, we present a case of a 58-year-old male patient with oculocutaneous albinism, keratoconus, total cataract, and glaucoma originating from father-daughter incest. He underwent femtosecond laser-assisted keratoplasty with "open-sky" cataract extraction and posterior chamber intraocular lens implantation. One week after surgery his uncorrected visual acuity improved from hand motion to 20/200. Six months later corneal K values were 49.1 D in the flat and 50.0 D in the steep meridian. The graft had a central corneal thickness of 488 µm and was well fitted. The patient's quality of life improved substantially due to the surgery. To the best of our knowledge, this is the first report on the association of albinism with advanced keratoconus, total cataract, and glaucoma. Moreover, no previous report on femtosecond laser-assisted keratoplasty using VisuMax femtosecond laser system with "open-sky" cataract extraction is available in the literature. The VisuMax femtosecond laser-assisted keratoplasty ensures fast patient rehabilitation in such challenging cases.


Assuntos
Albinismo Oculocutâneo/complicações , Extração de Catarata/métodos , Transplante de Córnea/métodos , Ceratocone/cirurgia , Terapia a Laser/métodos , Acuidade Visual , Humanos , Ceratocone/complicações , Masculino , Pessoa de Meia-Idade
7.
PLoS One ; 11(4): e0153186, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27074131

RESUMO

PURPOSE: To compare the concentrations of 11 tear mediators in order to reveal the biochemical difference between pellucid marginal degeneration (PMD) and keratoconus (KC). METHODS: We have designed a cross-sectional study in which patients with corneal ectasia based on slit-lamp biomicroscopy and Pentacam HR (keratometry values (K1, K2, Kmax), astigmatism, minimal radius of curvature (Rmin), corneal thickness (Apex and Min), indices (surface variation, vertical asymmetry, keratoconus, central keratoconus, height asymmetry and decentration)) were enrolled. Eyes of keratoconic patients were similar to the PMD patients in age and severity (K2, Kmax and Rmin). Non-stimulated tear samples were collected from nine eyes of seven PMD patients, 55 eyes of 55 KC patients and 24 eyes of 24 healthy controls. The mediators' (interleukin -6, -10, chemokine ligand 5, -8, -10, matrix metalloproteinase (MMP) -9, -13, tissue inhibitor of metalloproteinases (TIMP)-1, tissue plasminogen activator, plasminogen activator inhibitor, nerve growth factor) concentrations were measured using Cytometric Bead Array. RESULTS: MMP-9 was the only mediator which presented relevant variances between the two patient groups (p = 0.005). The ratios of MMP-9 and TIMP-1 were 2.45, 0.40 and 0.23 in PMD, KC and the controls, respectively. CONCLUSION: As far as we are aware, this is the first study that aims to reveal the biochemical differences between PMD and KC. Further studies of biomarkers to investigate the precise role of these mediators need to be defined, and it is important to confirm the observed changes in a larger study to gain further insights into the molecular alterations in PMD.


Assuntos
Córnea/metabolismo , Doenças da Córnea/diagnóstico , Ceratocone/diagnóstico , Lágrimas/metabolismo , Adulto , Idoso , Doenças da Córnea/metabolismo , Topografia da Córnea , Estudos Transversais , Diagnóstico Diferencial , Feminino , Humanos , Ceratocone/metabolismo , Masculino , Metaloproteinase 9 da Matriz/metabolismo , Pessoa de Meia-Idade , Inibidor Tecidual de Metaloproteinase-1/metabolismo
8.
J Ophthalmol ; 2016: 9392640, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26881061

RESUMO

Purpose. To determine associations between mediators in tears in the whole spectrum of keratoconus (KC); to explore connections between mediators and Scheimpflug parameters; to examine correlations between Scheimpflug parameters and bronchial asthma. Methods. Tear samples were collected from 69 patients and 19 controls. Concentrations of mediators-IL-6, -10; CXCL8, CCL5; MMP-9, -13; TIMP-1; t-PA, PAI-1-were measured by Cytometric Bead Array. Measured Pentacam parameters include keratometry values (K 1, K 2, K max), corneal thickness (Pachy Pupil, Apex, Min), and elevations and indices (including Belin-Ambrósio deviation (BAD-D)). Results. A number of significant positive associations were observed between pairs of mediator concentrations. Significant positive correlations were found between BAD-D and CXCL8/MMP-9 and K 2 and MMP-9. Significant negative associations were explored between Pachy Min and CXCL8/t-PA. Significant associations were found between pairs of mediators (IL-6 and CXCL8; CCL5 and CXCL8/MMP-9; TIMP-1 and MMP-9/-13/t-PA; t-PA and CXCL8/CCL5/PAI-1) and the severity of KC. Significant positive correlation between asthma and the severity of KC was explored. Conclusion. Cooperation of different mediators in tears all taking part in the complex pathomechanism of keratoconus was revealed. Our research verifies that inflammation plays a crucial role in the pathogenesis of KC. Additionally this study confirms the effect of bronchial asthma on keratoconus.

9.
Eur J Ophthalmol ; 24(5): 676-81, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24474379

RESUMO

PURPOSE: To assess astigmatism induced by paired opposite clear corneal incision (OCCI) compared to single incisions and to investigate factors on which its effect depends. METHODS: The study comprised 326 eyes from 326 patients. In patients with <1.0 D corneal astigmatism, clear corneal incision was performed (CC group, n = 245), and in those with >1.0 D preoperative corneal astigmatism, a second, opposite clear corneal incision was made (OCCI group, n = 81). Both groups consisted of superior, temporal, and oblique subgroups according to the steepest meridian. Prior to the surgery, and after surgery, repeated keratometry was performed and surgically induced astigmatism (SIA) was calculated using vector analysis. RESULTS: Two weeks after the surgery, the SIA was 0.67 ± 0.44 D in the CC group and 1.15 ± 0.65 D in the OCCI group; 9 weeks after the operation, it was 0.61 ± 0.43 D in the CC group and 0.99 ± 0.57 D in the OCCI group (p<0.001). The SIA showed no significant postoperative change in our groups. CONCLUSIONS: Opposite clear corneal incision reliably induces about 1.0 D of corneal astigmatism on the steep meridian in proportion to the rate of preoperative astigmatism. Its magnitude is independent of the location of the incisions and its effect remains unchanged during the postoperative period.


Assuntos
Astigmatismo/etiologia , Córnea/cirurgia , Complicações Intraoperatórias , Implante de Lente Intraocular , Facoemulsificação/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/fisiopatologia , Córnea/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Refração Ocular/fisiologia , Fatores de Tempo , Acuidade Visual/fisiologia
10.
Ophthalmic Res ; 51(1): 46-51, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24247644

RESUMO

PURPOSE: To study the association between different types of mediators in the tear fluid and topographic indices characterizing the severity of keratoconus (KC). METHODS: In this study, nonstimulated tear fluid samples were collected from 14 eyes of 11 patients with KC. The following indices were measured by corneal topography: maximum K value, average K value, Klyce/Maeda keratoconus index (KCI), Smolek/Klyce keratoconus severity index, opposite sector index, center/surround index, keratoconus prediction index and standard deviation of corneal power. The concentrations of interleukin (IL)-6, IL-13, CXCL8 (IL-8), chemokine (C-C motif) ligand 5 (CCL5, regulated and normal T cell expressed and secreted), matrix metalloproteinase-9 (MMP-9), MMP-13, tissue inhibitor of metalloproteinase-1, nerve growth factor (NGF) and epidermal growth factor were measured by cytometric bead array technology. Release of mediators was calculated from their concentrations and the volume of tears collected over 2 min. RESULTS: Significant positive associations were found between CCL5, MMP-13 and NGF and several topographic indices. Significant negative correlations were found between IL-6 and KCI. Age-dependent associations were observed between IL-13, CXCL8, CCL5 and MMP-13 and the topographic data. CONCLUSION: Several correlations were observed between the mediators and the topographic indices, suggesting possible roles in the pathophysiology of KC. Our data indicate that some mediators have different effects on the severity of disease in an age-dependent manner.


Assuntos
Proteínas do Olho/análise , Ceratocone/metabolismo , Metaloproteinases da Matriz/análise , Lágrimas/química , Adulto , Topografia da Córnea , Citocinas/análise , Feminino , Humanos , Peptídeos e Proteínas de Sinalização Intercelular/análise , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Índice de Gravidade de Doença , Inibidor Tecidual de Metaloproteinase-1/análise , Adulto Jovem
11.
PLoS One ; 8(10): e76333, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24124547

RESUMO

Keratoconus (KC) is the most common primary corneal ectatic disease which has considerable importance in public health. Corneal collagen crosslinking (CXL) is a procedure to mitigate progression of KC and reduce demand for corneal transplantation. Although studies have proven the efficacy of CXL regarding corneal shape, none have investigated the effects of CXL on tear biomarkers which are useful tools to understand molecular mechanisms behind CXL. Our purpose was to determine the effect of CXL on tear mediators in patients with KC and analyze associations with corneal changes. Tear samples were collected pre-CXL from 26 eyes of 23 patients and during a 12-month follow-up. The mediators' concentration was measured by Cytometric Bead Array technology. Corneal topography parameters measured by Scheimpflug Camera included: Thinnest-corneal-thickness (ThCT), keratometry values (K1, K2), Radii-Minimum (Rmin), Keratoconus-Index (KI), Center-KI (CKI), Index-of-Height Asymmetry (IHA) and Index-of-Surface Variance (ISV). At baseline, KI was correlated negatively with chemokine (C-C motif) ligand 5 (CCL5) (p=0.015) and matrix metalloproteinase (MMP)-13 (p=0.007). At day 4, interleukin (IL)-6 and IL-8 increased, while IL-13, IL-17A, interferon (IFN)-γ, CCL5, MMP-13, epidermal growth factor (EGF), nerve growth factor (NGF) and plasminogen activator inhibitor (PAI-1) decreased significantly compared to pre-CXL concentrations (p≤0.02). At 6 months tissue plasminogen activator (t-PA) increased (p=0.02), while at 12 months Rmin increased (p≤0.004), and IL-6 and CXCL8 (p=0.005 and p=0.047) as well as K1, ISV and KI decreased. After 6 months CKI and ISV showed significant associations with IL-17A; CKI with IL-13 and ThCT with IL-13 (p≤0.02), while at 12 months there were reverse associations between ThCT and IL-6, IL-13, INFγ, CCL5 and PAI-1 (p≤0.02). Alterations of mediators in tear fluid after CXL associate with topographic changes highlight the fact that many mediators are involved in the complex mechanisms after CXL. Further studies on biomarkers to investigate the efficacy of CXL are needed.


Assuntos
Córnea/metabolismo , Ceratocone/metabolismo , Lágrimas/metabolismo , Adolescente , Adulto , Idoso , Biomarcadores/metabolismo , Estudos de Casos e Controles , Colágeno/metabolismo , Córnea/patologia , Seguimentos , Humanos , Ceratocone/patologia , Pessoa de Meia-Idade , Adulto Jovem
12.
Eye Contact Lens ; 39(2): 147-52, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23411991

RESUMO

OBJECTIVES: The release of different cytokines and mediators in tears of patients with keratoconus (KC) wearing contact lenses (CLs) may contribute to the pathology of KC. METHODS: Cohort study was established in patients with KC wearing rigid gas permeable (RGP) CL (group I), patients with ametropia wearing silicone hydrogel (Si-Hi) CL (group II) and ametropic patients wearing RGP CL (group III). RESULTS: Our findings indicate that before CL wear, the release of epidermal growth factor (EGF) and tissue-type plasminogen activator (t-PA) was attenuated, whereas matrix metalloproteinase (MMP)-9, interleukin (IL)-6, chemokine (C-C motif) ligand 5 (CCL5), IL-13, and plasminogen activator inhibitor (PAI)-1 were enhanced in KC compared with ametropes. An increasing linear trend over time was found for MMP-9, EGF, and CXCL8 in KC and MMP-9, MMP-13, IL-6, and CXCL8 in group III. Significant differences were observed in the linear trend over time between groups I and III for MMP-13 and tissue inhibitor of metalloproteinases (TIMP)-1; between groups I and II for MMP-9 and CXCL8; and between groups III and II for MMP-9, CXCL8, and MMP-13. In KC, the release of MMP-9 at week 6 and nerve growth factor (NGF) at 10 min was higher, but NGF at week 2 was lower than that in group II. The release of MMP-13 and NGF at week 2 and 6 were lower in the KC group as compared with group III, and similarly, with IL-6 and CXCL8 at week 2 and PAI at all time points. CONCLUSIONS: Contact lens wear can influence the levels and dynamics of various mediators in the tears of patients with KC that might have an impact on the progression of the disease.


Assuntos
Lentes de Contato Hidrofílicas , Ceratocone/metabolismo , Lágrimas/metabolismo , Adulto , Análise de Variância , Biomarcadores/metabolismo , Estudos de Coortes , Citocinas/metabolismo , Proteínas do Olho/metabolismo , Feminino , Humanos , Masculino , Metaloproteinases da Matriz/metabolismo , Pessoa de Meia-Idade , Adulto Jovem
13.
Graefes Arch Clin Exp Ophthalmol ; 251(3): 917-22, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23229830

RESUMO

PURPOSE: P-selectin receptor is expressed in platelets and endothelial cells in a cell-activation-dependent manner. Platelet P-selectin (CD62) levels may become elevated in a number of vasoocclusive diseases, including arteriosclerosis, atherothrombosis, and diabetes mellitus (DM). Nonarteritic anterior ischemic optic neuropathy (NAION) is associated with a sudden loss of vision due to the vascular insufficiency of ciliary arteries supplying the optic nerve. In this study, our aim was to investigate the presence of increased platelet reactivity in the development of NAION. METHODS: Twenty-one NAION patients, 39 healthy control subjects, and 44 patients suffering from diabetes mellitus (DM) were examined in our case-control, pilot study. Platelet activation was investigated by flow cytometric analysis of the mean fluorescence intensity (MFI) of CD62 on platelets. These results were compared among the different study groups. RESULTS: NAION patients showed considerably although not significantly (p = 0.2017) higher P-selectin MFI values (71.98 ± 40.30) versus healthy subjects (55.48 ± 20.95), insulin-dependent DM patients (50.02 ± 13.08), and non-insulin-dependent DM subjects (54.72 ± 24.74). However, logistic regression analysis resulted in a statistically significant adjusted effect on the odds of NAION when CD62 MFI values were logarithmically transformed (OR: 3.86, 95 % CI: 1.10 to 13.53, p = 0.0346). CONCLUSION: Elevated platelet CD62 positivity may be related to NAION, suggesting a possible role of enlarged platelet activity in the generation of this type of ischemic optic neuropathy.


Assuntos
Plaquetas/metabolismo , Neuropatia Óptica Isquêmica/sangue , Selectina-P/sangue , Idoso , Arterite/sangue , Estudos de Casos e Controles , Diabetes Mellitus/sangue , Feminino , Citometria de Fluxo , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Ativação Plaquetária , Fatores de Risco , Acuidade Visual/fisiologia
14.
Cornea ; 31(1): 36-41, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22081146

RESUMO

PURPOSE: To determine the reliability and repeatability of keratometry (K) measurements obtained with the Pentacam high resolution (HR), automated keratometry, and corneal topography systems. METHODS: The right eyes of 46 healthy subjects were examined prospectively. Keratometry measurements in the flat (Kf) and steep (Ks) meridians were taken by 2 independent investigators with the Pentacam HR (Oculus, Wetzlar, Germany) followed by automated keratorefractometry (KR-8100; Topcon, Tokyo, Japan), and corneal topography (TMS-4; Tomey, Erlangen, Germany). RESULTS: The mean K readings of the Pentacam HR, automated keratometry, and corneal topography were 43.40/43.34 diopter (D), 43.99/43.98 D, and 43.80/43.83 D, respectively. The difference between the values was statistically significant (P < 0.0001, repeated measures analysis of variance). Strong significant correlation was observed between the Pentacam HR and keratometry (Kf: r = 0.952/0.954; Ks: r = 0.845, Spearman rank test), and Pentacam HR and corneal topography (Kf: r = 0.933/0.930; Ks: r = 0.838/0.829) (P < 0.0001). No significant difference was presented between the 2 investigators for any of the instruments (P = 0.215-0.983). Moreover, high correlation was found between the K readings of the observers (interoperator intraclass correlation coefficients ranged from 0.95 to 0.99). CONCLUSIONS: The Pentacam HR provided reliable K measurements in clinical practice in comparison with an automated keratometer and a corneal topographer. Based on the results, for patient follow-up, one keratometry device is recommended.


Assuntos
Topografia da Córnea/métodos , Fotografação/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Refração Ocular/fisiologia , Reprodutibilidade dos Testes , Adulto Jovem
15.
J Cataract Refract Surg ; 33(3): 443-7, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17321395

RESUMO

PURPOSE: To measure anterior chamber depth (ACD) with an anterior segment optical coherence tomography (AS-OCT) and a standard ultrasonic (US) axial scan (A-scan) device using an immersion technique and to assess repeatability, reproducibility, and correlations of the measurements. SETTING: Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS: Sixty healthy eyes of 41 patients were enrolled in a study. The central ACD was measured 5 times with AS-OCT (Visante, Carl Zeiss Meditec) using its chamber tool and 5 times with a US A-scan device (UltraScan Imaging System, Alcon Laboratories) using an immersion method. The measurements were performed consecutively by 2 independent observers. RESULTS: The mean ACD measured with AS-OCT was 3.12 mm +/- 0.33 (SD) by observer 1 and 3.11 +/- 0.33 mm by observer 2 (P = .78). The repeatability was 0.8% +/- 0.4% and 1.9% +/- 1.4%, respectively. The reproducibility was 0.23%. The reliability coefficient with AS-OCT was 99.6%. The mean ACD measured with immersion US A-scan was 2.98 +/- 0.33 mm by observer 1 and 2.95 +/- 0.34 mm by observer 2 (P = .68) . The repeatability was 6.4% +/- 3.8% by observer 1 and 8.5% +/- 4.9% by observer 2. The reproducibility was 0.88%. The reliability coefficient was 87.1% for US A-scan measurements. The difference between ACD values with AS-OCT and values with US A-scan was statistically significant (P = .02). The correlation (r) between AS-OCT and US A-scan was 0.732 (P<.0001) by observer 1 and 0.802 (P<.0001) by observer 2. CONCLUSIONS: Anterior chamber measurements were significantly deeper with AS-OCT than with US immersion A-scan. Repeatability of ACD measurements was better with AS-OCT than with immersion US, and reproducibility was equal with the 2 methods.


Assuntos
Câmara Anterior/diagnóstico por imagem , Técnicas de Diagnóstico Oftalmológico , Tomografia de Coerência Óptica/métodos , Antropometria/métodos , Biometria , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ultrassonografia/métodos
16.
J Cataract Refract Surg ; 32(8): 1331-5, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16863970

RESUMO

PURPOSE: To compare anterior chamber depth (ACD) measurements with a new optical device with those taken with a standard ultrasound (US) device in emmetropic phakic and pseudophakic eyes. SETTING: Department of Ophthalmology, Medical Health and Science Center, University of Debrecen, Debrecen, Hungary. METHODS: Forty-two phakic and 42 pseudophakic patients with normal axial lengths (mean 22.91 mm +/- 1.21 [SD]) were enrolled in the study. The ACD was measured 3 times with Scheimpflug-based Pentacam (Oculus) and then 3 times with a standard A-scan US device (AL-2000, Tomey). The data were then analyzed. RESULTS: In the phakic group, the mean ACD was 2.87 +/- 0.4 mm with the Pentacam and 2.89 +/- 0.49 mm with ultrasound A-scan (US) (P = .84). In the pseudophakic group, the mean ACD was 3.41 +/- 0.28 mm and 3.97 +/- 0.45 mm, respectively (P < .001). The correlation between measurements was significant in both the phakic and pseudophakic groups (r = .547/P < .001 and r = .404/P = .01, respectively). CONCLUSIONS: In phakic eyes, ACD measured with the Pentacam and with US was the same. However, in pseudophakic eyes, the difference was significantly lower when the ACD was measured with the Pentacam. Therefore, in pseudophakic patients, further evaluation of ACD data with the Scheimpflug-based system is necessary.


Assuntos
Câmara Anterior/anatomia & histologia , Antropometria/métodos , Cristalino/fisiologia , Pseudofacia/patologia , Idoso , Câmara Anterior/diagnóstico por imagem , Biometria , Técnicas de Diagnóstico Oftalmológico , Humanos , Implante de Lente Intraocular , Dispositivos Ópticos , Facoemulsificação , Fotografação , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...